SPECIFICATIONS : CAS BSA LOAD CELL

Max. Capacity 250, 500kgf, 1, 2, 3, 5, 10tf
Rated Output 3.0 ± 0.0075mV/V
Zero Balance 0 ± 0.03mV/V
Accuracy Class D3 C3
Combined Error 0.03% 0.025%
Repeatability 0.01% 0.01%
Creep for 30 min 0.03% 0.017#
Temperature Effect on :
Zero Value
Output Value
0.028%/10°C
0.015%/10°C
0.014%/10°C
0.011%/10°C
Excitation :
Recommended
Maximum
10V
15V
Resistance :
Input
Output
Insulation
350 ± 3.5Ω
350 ± 3.5Ω
≥ 2.000MΩ
Compensated Temperature Range – 10 ~ 40°C
Operating Temperature Range – 30 ~ 80°C

FEATURES

OPTIONS

OIML C3 approved (OIML R60) Pivot end loading version (-Tend)
Protection class IP66  

TYPE : CAS BSA LOAD CELL

Model Capacity A B C D E F G H I J K
BS-250L 250kgf 25.4 76.2 130 32 32 15.8 13.5 13.5 16.0 M12 x 1.75 52
BS-500L 500kgf 25.4 76.2 130 32 32 15.8 13.5 13.5 16.0 M12 x 1.75 52
BS-1 1tf 25.4 76.2 130 32 32 15.8 13.5 13.5 16.0 M12 x 1.75 52
BS-2 2tf 25.4 76.2 130 32 32 15.8 13.5 13.5 16.0 M12 x 1.75 52
BS-3 3tf 28.1 95.3 171.5 38 38 19 20 20 19 M18 x 1.5 76.2
BS-5 5tf 28.1 95.3 171.5 38 38 19 20 20 19 M18 x 1.5 76.2